The attaching roof is at a 3 1 2 over 12 slope.
Step flashing metal roof brick side wall.
It is used to seal the gap between walls and intersecting roofs.
Metal roof flashing is a galvanized sheet metal that is bent at a 90 degree angle about 8 to 12 inches on each side of the angle.
Here s how to install it correctly.
Once the roofing and step flashing are in place complete the counterflashing at the masonry as follows.
Step flashing is used to provide a water tight connection where roofing adjoins a vertical juncture.
It s one of the more important trims that we re going to use on the sl 16 installation.
Vent flashing done right to prevent leaks back up roof vent boots with flashing counterflashing and proper shingling.
In order to install the counter flashing the roofer cut a diagonal line 3 4 deep to match the roof slope.
You can hire a professional to install it against a brick wall or you can do it yourself.
Continue reading below our video of the day step 1 choose what kind of metal flashing you need.
That lip is then set into a reglet or groove in this case cut into the mortar joint of the brick wall above.
Bent into an l shape.
You ll notice that there is paint on one side and primer on the other.
It can be used to attach the final trim for end walls side walls gable trim and hips so it s used quite a bit.
Hook a hem at the top into the hem in the edge of the pan flashing inset.
We re going to focus on the z trim for just a moment.
Metal roof flashing is a galvanized sheet metal bent at right angles with about eight to 12 inches on each side of the angle.
Installing step flashing to prevent roof leaks step flashing spans the joint between roof shingles and an adjacent side wall.
We use straight l aluminum wall metal but it get 6 of roofing cement and every shingle gets counter bulled.
Galvanized sheet metal bent at a 90 degree angle i e.
This flashing is typically field fabricated from a sheet of 26 ga.
A hipped standing seam metal roof attaching to the taller main body of the house at a brick veneer wall.
The horizontal part of the flashing will vary depending on the type of roof covering material.
Posted march 4 2017 filed under roof installation roof repair maintenance.
Install metal counterflashing onto the face of the block extending it down to about inch above the shingles.
To install the roof wall flashing above the builder bent the top edge of the flashing into a 90 degree lip about 2 cm in width.
Sidewall flashing a sidewall is a junction between a wall and a sloped portion of a roof.