The installation steps are as follows.
Spray insulation roof deck.
The later is used in new construction as the interior board serves as an inner wall.
As air impermeable insulation spray foam insulation can be used in such applications.
Bare foam board one sided sheathing board or double sided which is also reference as structural insulated panels.
Air permeable insulation applied to the underside of the roof deck with minimum r 10 rigid insulation above the roof deck.
Most unvented attics incorporate spray polyurethane foam spf on the underside of the roof deck and attic walls.
It s not coming from above the roof and it s not some new moisture source resulting from the spray foam.
Air permeable insulation applied to the under side of minimum r 10 air impermeable insula tion spray foam or rigid board which is applied directly to the underside of the roof deck.
Remove existing roofing and non adhered underlayment to expose roof sheathing.
Spray foam insulation applied on the underside of the roof deck in cold climate commercial buildings allows for a significant reduction in condensation potential particularly compared to interior air permeable batt systems.
Lstiburek takes blame for bad language.
Insulate an attic in an existing home by installing spray foam open cell or closed cell on the underside of the roof deck.
The spray foam can also serve as the thermal and vapor control layers in both new and retrofit construction.
The last requirement is the installation of your shingles must be performed in strict accordance with the owens corning installation instructions.
When the choice is made to insulate along the underside of the roof deck spray foams have advantages over other insulation types because of the ability of spray foams to effectively air seal complex assemblies.
Yeah you probably still breathed some of it but not as much as you will now with spray foam on the roof deck.
You may have odor problems.
This construction approach was first used in the 1970s and it has been implemented much more widely since it was first included in the international code council s icc model building code in 2007 irc section 806 4.
Install insulating sheathing above the roof deck on existing homes.
This measure will convert a vented attic to a nonvented attic.
Your indoor air quality may get worse.
By encapsulating the attic and leaving the old insulation up there that filth is in your conditioned space.
Inspect the existing roof shingles or roofing membrane for any deficiencies.
This retrofit assembly is appropriate for homes with conditioned attics or where the retrofit is intended to create a conditioned attic.
Moisture generated indoors or that infiltrates into the home is responsible for the bulk of the moisture in an attic insulated with spray foam on the underside of the roof sheathing.